by | Sep 27, 2025
= Ch
ce ET oneves v@ Chem
a Trend
Release Innovation
a
PRODUCT DATA |
Chemlease PMR-90 EZ
Semi-Permanent Release Agent
Description 7. Allow 30 minutes for full cure. Proceed with
Chemlease PMR-90 EZ is a rapid curing semi- production.
permanent mold release agent that provides multiple
releases with minimal transfer to the molded part. Touch-Up Coats
Chemlease PMR-90 EZ is the highest slip version of Reapply one light coat as requir forfi
the Chemlease PMR family; primarily for closed cca y 9 quired and cure. 2s for final
molding of abrasive or low draft parts. 7
Notes
Benefits Time will vary with room and mold temperature. Wipe off as.
. the solvent begins to evaporate. If the release agent is left
HAPs Free on too long, you may notice some smearing or streaking. To
High thermal stability remove the smear or streak, rub the affected area with the
Easy to apply recommended Chemlease release agent, and then simply
* Multiple releases between applications. remove the excess sooner than you had before.
Reduces labor time and cost
im,
* HAPs are not formula constituents of this product. Standard Important .
manufacturing processes may result in trace quantities The recommended number of coats and cure times
[<0 .1%] of HAPs. are a general guideline found to be more than
sufficient in a broad spectrum of molding conditions.
Chemlease solvent carriers contain no Class | or II When molding products with extreme geometries or
registered ozone depleting substances. experiencing low-humidity conditions in the shop, the
customer may find the need to extend the cure time
Mold Preparation between coats and increase the number of coats
1, Clean mold surface to remove all traces of waxes, @pplied to the mold. The efficiency of a release film is
release agents and sealers. best determined through a combination of tape tests
2. Clean mold with Chemlease Mold Cleaner. and experimentation.
3. Apply the appropriate Chemlease Sealer to new Storage
or porous molds (contact a Sales Rep or . .
Distributor for details). Do not store above 49 C/120 F. Keep container
tightly sealed to prevent evaporation and/or
age contamination. If stored in cold temperatures, allow to
Application For Base Coats warm to room temperature before using.
1. Mold surface must be thoroughly cleaned to
remove all traces of wax, release agents, and other Packaging
sealers. e . - A
2. Surface should be dry and free of contaminants. Chemlease PMR-90 EZ is available in 1-gallon, 5-
3. Saturate clean cotton cloth (not dripping) and wipe gallon, and 55-gallon quantities.
on a smooth continuous film. Apply no more than
a few square feet at a time. Safety Data
4. When the film begins to evaporate at the edge, Material Safety Data Sheets are available for all
wipe the surface with a second clean dry cotton Chemlease products and should be consulted prior to
cloth. Use a circular motion from the outside, use of the product.
working inwards until film is left dry and clear. See
Notes. While the technical information and suggestions for use contained
il enti herein are believed to be accurate and reliable, nothing stated in this
5. Repeat above procedures until entire mold surface bulletin is to be taken as a warranty either expressed or implied.
has been covered.
6. Apply.4-5 coats, allowing 15 minutes between each
complete coat.
Chem-Trend LP.
120709 1445 W. McPherson Park Drive, P.O. Box 860, Howell, Ml 48844,0860
Telephone: 517.546.4520 Facsimile: 517.548.5370 US/Canada: 800.727.7730
www.chemtrend.com Copyright 2004 Chem-Trend L.P., All Rights Reserved
by | Sep 27, 2025
(@ Chem
Release Innovation
PRODUCT DATA
Chemlease PMR EZ
Release Agent
Description Test To Ensure Proper Application
Chemlease PMR EZ is a unique semi permanent mold Attach a small strip of masking tape to different areas of the
release system developed specifically for the composites mold. There should be very little resistance when removing
industry, for use where a high quality finish is required. the tape if proper release is applied. Compare to an untreated
mold. (Tape should adhere to untreated mold).
Benefits
+ HAPs free* Touch-Up Coats
+ Multiple releases between applications Once in production the release film will begin to wear. Rather
+ Easy to apply than applying a touch-up coat once the parts begin to stick, it
* Eliminates the use of wax is better to do preventative maintenance. For example, if trials
+ Reduces labor time and costs determine that 20 releases are obtainable between touch-up
+ Provides excellent gloss coats, it is better to reapply a touch-up coat after every 15
* High temperature stability cycles or at the end of every second shift. The above-
+ Does not build up on the mold surface described action will keep the molds in production longer and
* Minimal transfer to molded part help establish a routine of quality preventative maintenance.
* HAPs are not formula constituents of this product. Standard Important
manufacturing processes may result in trace quantities [<0 .1%] of The recommended number of coats and cure times area
general guideline found to be more than sufficient in a broad
Chemlease solvent carriers contain no Class Jor Il registered Spectrum of molding conditions. When molding products with
ozone depleting substances extreme geometries or experiencing low-humidity conditions in
the shop, the customer may find the need to extend the cure
Mold Preparation time between coats and increase the number of coats applied
to the mold. The efficiency of a release film is best determined
1. Mold surfaces should be thoroughly cleaned to remove all oar A
traces of wan, release agente, saalers and bung through a combination of tape tests and experimentation.
compounds.
2. Do a final cleaning of mold surface with Chemlease Mold Storage
Cleaner. Do not store at temperatures above 49 C/120 F. Keep
3. Seal mold with the appropriate Chemlease Sealer. container tightly sealed to prevent evaporation and/or
contamination. If stored in cold temperatures allow warming to
Application For Base Coats room temperature before using.
1. Mold surface must be thoroughly cleaned to remove all Packaging
traces of wax, release agents, and other sealers. ee
2. Surana shoud be diy aut rea of contaminants Chemlease materials are available in 1-gallon, 5-gallon, and
Se ee ot eat ananars 55-gallon containers. The material should always be clear. If
apekrenansneeha (ro ripping) an py ated cloudiness is detected, please contact a Chemlease
smooth continuous film. Apply no more than a few square Technical Representative,
feet at a time.
4. When the film begins to evaporate at the edge, wipe the
surface with a second clean dry cotton cloth. Use a
circular motion from the outside, working inwards untilfim Safety Data ;
ig left dry and clear. See Notes. Material Safety Data Sheets are available for all Chemlease'
5. Repeat above procedures until entire mold surface has Products and should be consulted prior to use of the product.
been covered.
6. Apply 4-5 coats, allowing 15 minutes between each
complete coat. While the technical infc ition and suggest for ined here
ie the technical information and suggestions for use contained herein are
7. Allow 30 minutes for full cure. Proceed with production. Yee echnical dormetn end sungeetone for use cemtnedbarein 2
a warranty either expressed or implied.
Notes
Time will vary with room and mold temperature. Wipe off as
the solvent begins to evaporate. If the release agents left on
too long, you may notice some smearing or streaking. To
remove the smear or streak, rub the affected area with the
recommended Chemlease release agent, and then simply
remove the excess sooner than you had before.
Chem-Trend L.P.
121608 1445 W. McPherson Park Drive, P.O. Box 860, Howell, MI 48844.0860
Telephone: 517.546.4520 Facsimile: 517.548.5370 US/Canada: 800.727.7730
www.chemtrend.com Copyright 2004 Chem-Trend L-P., All Rights Reserved
by | Sep 27, 2025
Updated: 2017
Stabond MR3
Technical Data Sheet
DESCRIPTION
Stabond Mold Release #3 has been developed to facilitate the removal of polyurethane parts from a mold.
PROPERTIES
TYPE: WAX SHELF LIFE: 12 MONTHS
COLOR: WHITE THINNER: STABOND T-THINNER
SOLIDS: 10% VISCOSITY: VERY THIN SYRUP
COVERAGE: 300 SQ. FT. /GALLON FLASH POINT: < 0 F
WT/GAL: 6.09 lbs
APPLICATION
The mold should be thoroughly cleaned and dried. Preheat the mold to 120 F. Either brush or spray the mold release to the warm,
dry surface. Then warm the mold and drive off the solvent by blowing air over the surface. The mold is now ready for use. Porous molds
e.g. Plaster of Paris, are not recommended, but if used, must first be sealed with lacquer or similar coating.
STORAGE
For maximum shelf life, store material in cool dry area and keep container tightly sealed. Storage temperature of 60 -80 F. is
recommended. Lower storage temperature will cause a temporary increase in viscosity. Rotate stock on a First in First out basis. For
optimum results agitate adhesive prior to use.
DANGER
Extremely flammable. Toxic. Vapors may ignite explosively. Provide fresh air cross ventilation to prevent build-up of vapors. Keep away
from heat, sparks and from open flame. Do not smoke. Extinguish all flames and pilot lights and turn off all non-explosion proof
electrical equipment and sources of ignition during use and until vapors are dissipated. Avoid prolonged or repeated breathing of
vapors. Close container after use. Contains aromatic and aliphatic hydrocarbons. KEEP OUT OF REACH OF CHILDREN. Harmful or fatal
if swallowed. If swallowed do not induce vomiting, seek immediate medical attention. THOROUGHLY READ THE SDS FOR THIS
PRODUCT PRIOR TO USING IT.
IMPORTANT
Suggestions for the use of this product are based on tests believed to be reliable; however, the user should determine suitability for
the intended use by his own evaluation. Because the use of the material is beyond our control, neither the seller nor the manufacturer
shall be liable for any injury, loss, or damage, direct or consequential, arising out of the use or inability to use this product. Seller and
manufacturer s sole obligation shall be replacement of material proved to be defective.
by | Sep 27, 2025
1.
Chem-Trend L.P.
1445 W. McPherson Park Drive, P.O. Box 860, Howell, MI 48844.0860
Telephone: 517.546.4520 Facsimile: 517.548.5370 US/Canada: 800.727.7730
Copyright 2004 Chem-Trend L.P., All Rights Reserved
040107
www.chemtrend.com
Chemlease
MPP2180 Sealer
Mold Prep and Primer
Chemlease
MPP2180 is formulated for sealing tooling in
both the FRP and advanced composites sectors.
Appropriate substrates include polyester gelcoat and non-
gelcoat, epoxy and phenolic mold surfaces, and most metals.
Chemlease
MPP2180 is not recommended for sealing
monolithic graphite or ceramic tooling.
General
Chemlease
MPP2180 should be applied onto a clean mold
surface. Chemlease
MPP2180 is an excellent sealing
material, but should not be used as a mold release agent.
Use of this product without a release agent may result in
severe damage to the mold. It has the ability to enhance the
performance of semi-permanent release agents. In many
cases, it has also been used as a means of re-surfacing a
worn-out mold. The appropriate Chemlease
releasant
should be applied on top of the product after it has been
cured. For sealing purposes, a wipe on/wipe off application
technique is used. To resurface a mold, use of a wipe
on/leave on technique is typical.
Mold Preparation
1.After the mold has been buffed and polished wi
th
rubbing and polishing compounds, wash t
he mold
surface thoroughly with clean water. The proper
water
wash will remove all fillers and wate
r-soluble
contaminants from the buffing an
d polishing
compounds. Use liberal amounts of water. Wipe dry
with clean cotton
cloths.
2.
Following the water wash, apply Chemlease
Mold
Cleaner to remove
all traces of solvent-soluble
contaminants such as waxes, silicones, oils, etc.
Use
liberal quantities of Mold Cleaner in a we
ll-ventilated
area, then wipe dry with clean cott
on cloths until the
mold is squeaky clean by thumb or hand rub test.
3.The wiping cloth should be changed regularly to e
nsure
that a clean, absorbent surface of the wi
ping cloth is
always presented to the mold surface. This proce
dure
prevents recontamination of the mold by wi
ping cloths
which carry cont
aminants lifted from the mold.
Application Instructions Wipe On/Leave On
1. Apply Chemlease
MPP2180 by wiping. Use clean, soft
cotton cloths. A wipe on/leave on
technique can be
used, even for Class A finish molds, applying to an
area of about four square feet at a time. Care shou
ld be
taken on large structures to ensure that the overla
p area
is as small as possible and that the product on the
area
overlapped has not already cured. Generally, 1 or
2
coats are sufficient to seal. Allow 30 minutes bet
ween
each coat. After the final coat, allow a 1-2 hour cu
re at
room temperature. The cure time can be reduced
to 20
minutes by warming mold to 120-140 F/49-60 C.
Note:
a prismatic sheen may develop on the mold surfac
e
using this method. This sheen does not imprint ont
o the
molded part in mo
st situations.
2.
When the product has cured, apply the appropriate
Chemlease
mold release. Please refer to the proper
Product Data Sheet for mold re
lease application details
and instructions.
Application Instructions Wipe On/ Wipe Off
Follow instructions for Wipe On/Leave On. However, after
material is wiped on, wipe off immediately using a clean, dry,
soft cotton cloth being careful to wipe off evenly. Change
cloths frequently for best results. Once material has begun to
dry and cure, it will not be possible to wipe off without
causing blemishes and streaks so it is important to wipe the
sealer off immediately after it has been wiped on and is still
wet. Generally, 1 or 2 wipe on/wipe off coats are sufficient to
seal.
Touch-Up Coats
Touch-up coats are not possible once this product is applied
and cured since a release agent must be applied over the top
of it before the mold can be used in production.
Cure Test
Under the best conditions, Chemlease
MPP2180 has been
found to cure in as little as one hour. A simple test method
for complete cure is: Apply one drop each of water and
Chemlease
Mold Cleaner onto a flange area that has been
coated with the product. Wait a few seconds then wipe off
with a clean cloth. If there is no evidence of the drops on the
tool surface, the product is completely cured.
Important
The recommended number of coats and cure times are a
general guideline found to be sufficient in a broad spectrum
of molding conditions. When molding products with extreme
geometries or experiencing low-humidity conditions in the
shop, the customer may find it necessary to extend the cure
time between coats and increase the number of coats applied
to the mold. The efficiency of a release film is best
determined through a combination of tape tests and
experimentation.
Storage
The container should be kept closed at all times when not in
use to prevent contamination, evaporation and/or premature
curing. Do not store at temperatures above 100 F/38 C.
Chemlease
MPP2180 is flammable. Keep away from heat,
sparks, flames and combustion sources during storage and
use. If stored in cold temperatures, allow to warm to room
temperature before using.
Packaging
Chemlease
MPP2180 is available in 1-quart (1-liter), 1-
gallon (4-liter), 5-gallon (20-liter) and 55-gallon (208-liter)
containers.
Safety Data
Material Safety Data Sheets are available for all
Chemlease
products and should be consulted prior to use
of the product.
While the technical information and suggestions for use contained
herein are believed to be accurate and reliable, nothing stated in this
bulletin is to be taken as a warranty either expressed or implied.
Chemlease
MPP2180
Mold Prep and Primer
by | Sep 27, 2025
Technical Data Sheet
+. .
Loctite Frekote B-15
Known as Frekote B-15
December 2013
PRODUCT DESCRIPTION Directions for use:
Loctite Frekote B-15 provides the following product 1. Loctite Frekote B-15 can be applied to mold surfaces
characteristics: _ by spraying, brushing, dipping or wiping with a clean, lint
Technology _ Mold Sealer _ free, cotton wiping cloth. When spraying, ensure a dry air
Appearance Clear, colorless”> source is used or use an airless spray system making
Chemical Type Solvent Based Polymer sure the nozzles is 20 to 25 cm from the mold surface.
[Odor SSSSC*SOent Sd 2. Brushing and dipping are effective methods of application,
Cure Room temperature cure but care should be taken to avoid excessive pooling and
Cured Thermal Stability |<400 C to ensure that the part is well drained. Wiping on is the
Application Mold Sealer = best method of application.
Application Temperature|20 to 60 C 7 3. Only a thin wet film is required. It is suggested that small
Specific Benefit No contaminating transfer areas be coated, working progressively from one mold to
# High thermal stability the other, , ,
Seals mold porosity, scratches| 4. Apply 8 of two coats, allowing 30 minutes
imperfect q
crimperfections _________| 5 The final coat will cure within 24 hours at 23 C or the cure
process can be shortened by baking the mold for 60
ito a o minutes at 95 C after ensuring that the mold is dry and all
Paapaae Frekote oe is formulated specifically asa Sealer sovents have flashed off.
for composite and metal molds with micro porosity problems, 6. The mold is now ready to be coated with Frekote mold
small surface scratches or imperfections. {sed in Sengunction release products. Please refer to individual product data
with other Frekote products, Loctite Frekote B-15 sheets for the proper application of the release agent.
provides an excellent base coat enhancing the release ae
ch up
advantages offered. Touch up coats with a sealer should only be applied to areas
where the mold was repaired. On repaired areas apply the
TYPICAL PROPERTIES OF UNCURED MATERIAL same number of sealer and release agent coats like for the
Specific Gravity @ 25 C 0.745 to 0.775" base coating onto new or refurbished molds.
- Loctite Material Specification >
Pash Point S22 =P8 LMS dated December 18, 2002. Test reports for each batch
Release Agent Transfer ques are available for the indicated properties. LMS test reports
include selected QC test parameters considered appropriate to
specifications for customer use. Additionally, comprehensive
controls are in place to assure product quality and
GENERAL INFORMATION . consistency. Special customer specification requirements may
This product is not recommended for use in pure oxygen be coordinated through Henkel Quality.
and/or oxygen rich systems and should not be selected as
a sealant for chlorine or other strong oxidizing materials.
For safe handling information on this product, consult the
Safety Data Sheet (SDS).
Mold Preparation
Cleaning:
Mold surfaces must be thoroughly cleaned and dried. All traces
of prior release must be removed. This may be accomplished
by using Loctite Frekote PMC or other suitable cleaner.
Loctite Frekote 915WB or light abrasives can be used for
heavy build-up.
by | Sep 27, 2025
. casey
(a Chem
Trend
– Release Innovation
Se
|
|
*hoDUCT DATA Ghemlease Mold Cleaner EZ
Description Handling and Storage
Chemlease Mold Cleaner EZ is a special blend of Chemlease Mold Cleaner EZ is flammable and must
HAP free* solvents designed to remove wax and be kept away from heat, sparks, and open flame. The
contaminants from composite molds. Chemlease can should be kept closed when not in use to prevent
Mold Cleaner EZ is ideal for preparing composite mold evaporation of flammable solvents. Store material in a
surfaces for the application of Chemlease mold cool location. Avoid breathing of vapor or spray mist
sealers and releasants. Chemlease Mold Cleaner EZ _ or prolonged contact with skin. Use only with
is also excellent for cleaning brushes and equipment. adequate ventilation. DO NOT take internally. In
confined areas, operators should wear respirators or
*HAPs are not formula constituents of this product. fresh air masks. Industrial grade solvent resistant
Standard manufacturing processes may result in trace gloves should be worn while using Chemlease
quantities [<0 .1%] of HAPs. materials.
Application Packaging
1. Chemlease Mold Cleaner EZ should be applied Chemlease Mold Cleaner EZis available in
to the mold surface with clean, 100% cotton 4-quart (1 liter), 1-gallon (4 liter), 5-gallon
cloths. While the mold surface is still wet, (20 liter) and 55-gallon (208 liter) containers.
vigorously wipe the mold dry with a second clean,
dry, 100% cotton cloth.
2. Frequently exchange saturated cloths with new, Safety Data
clean cloths. Material Safety Data Sheets are available for all
3. Repeat process several times (a minimum of two Chemlease products and should be consulted prior to
cleanings is recommended) until all residues (dirt, Se of the product.
dust, grease, moisture, etc.) are removed.
4. The mold is then ready for application with the
appropriate Chemlease Mold Sealer and/or
Chemlease Mold Release.
NOTE: While the technical information and suggestions for use contained
If you plan to use compounds or glazes, etc., prior to herein are believed to be accurate and reliable, nothing stated in this
applying Chemlease Mold Sealer and/or Chemlease _llletinis to be taken as a warranty either expressed or implied.
Mold Release, be sure to wipe clean with Chemlease
Mold Cleaner EZ after doing so, as most buffing
compounds will not allow Chemlease sealers and
release agents to work properly. Prolonged exposure
on the mold surface (puddling, dipping, etc.) should be
avoided.
Chem-Trend LP.
121608 1445 W. McPherson Park Drive, P.O. Box 860, Howell, Ml 48844.0860
Telephone: 517.546.4520 Facsimile: 517.548.5370 US/Canada: 800.727.7730
www.chemtrend.com Copyright 2004 Chem-Trend L-P., All Rights Reserved
by | Sep 27, 2025
Technical Data Sheet
+4
Loctite Frekote B-15
Known as Frekote B-15
December 2013
PRODUCT DESCRIPTION Directions for use:
Loctite Frekote B-15 provides the following product 1. Loctite Frekote B-15 can be applied to mold surfaces
characteristics: by spraying, brushing, dipping or wiping with a clean, lint
Technology Mold Sealer _ a free, cotton wiping cloth. When spraying, ensure a dry air
[Appearance ___[Clear, colorless _ source is used or use an airless spray system making
Chemical Type [Solvent Based Polymer sure the nozzles is 20 to 25 cm from the mold surface.
[Odor [Sovent 2. Brushing and dipping are effective methods of application,
(Cure [Room temperature cure | but care should be taken to avoid excessive pooling and
Cured Thermal Stability |<400 C to ensure that the part is well drained. Wiping on is the
Application Mold Sealer ae best method of application.
Application Temperature|20 to 60 C oo 3. Only a thin wet film is required. It is suggested that small
Specific Benefit No contaminating transfer areas be coated, working progressively from one mold to
| e High thermal stability ee - a
| * Seals mold porosity, scratches 4. Apply 2 of two coats, allowing 30 minutes
L_______ | _orimperfections _ 5. The final coat will cure within 24 hours at 23 C or the cure
process can be shortened by baking the mold for 60
Loctite Frekote B-15 is formulated specifically as a sealer minutes at 9eie after ensuring that the mold is dry and all
for composite and metal molds with micro porosity problems, 6. The mold is now ready to be coated with Frekote mold
small surface scratches or imperfections. Used in conjunction release products. Please refer to individual product data
with other Frekote products, Loctite Frekote B-15 sheets for the proper application of the release agent.
provides an excellent base coat enhancing the release
advantages offered Mold Touch up
7 Touch up coats with a sealer should only be applied to areas
where the mold was repaired. On repaired areas apply the
TYPICAL PROPERTIES OF UNCURED MATERIAL same number of sealer and release agent coats like for the
Specific Gravity @ 25 C 0.746 to 0.7750" base coating onto new or refurbished molds.
. Loctite Material Specification >
Flash Point – See SDS LMS dated December 18, 2002. Test reports for each batch
Release Agent Transfer aus are available for the indicated properties. LMS test reports
include selected QC test parameters considered appropriate to
specifications for customer use. Additionally, comprehensive
controls are in place to assure product quality and
GENERAL INFORMATION . consistency. Special customer specification requirements may
This product is not recommended for use in pure oxygen _be coordinated through Henkel Quality.
and/or oxygen rich systems and should not be selected as
a sealant for chlorine or other strong oxidizing materials.
For safe handling information on this product, consult the
Safety Data Sheet (SDS).
Mold Preparation
Cleaning:
Mold surfaces must be thoroughly cleaned and dried. Alll traces
of prior release must be removed. This may be accomplished
by using Loctite Frekote PMC or other suitable cleaner.
Loctite Frekote 915WB or light abrasives can be used for
heavy build-up.
a
by | Sep 27, 2025
TechnicalDataSheet
LOCTITE
FREKOTE700-NC
Knownas700-NC
January-2015
PRODUCTDESCRIPTION
LOCTITE
FREKOTE 700-NC providesthefollowing
productcharacteristics:
Technology MoldRelease
Appearance Clear,colorless
LMS
ChemicalType SolventBasedPolymer
Odor Solvent
Cure Romtemperaturecure
CuredThermalStability 400 C
Application ReleaseCoatings
ApplicationTemperature13 to135 C
SpecificBenefit Nochlorinatedsolvents
Highglossfinish
Highslip
Nocontaminatingtransfer
Nomoldbuild-up
LOCTITE
FREKOTE 700-NC offersexcellentrelease
propertiesforthemostdemandingapplicationsandisagreat
all-purposereleaseagent.LOCTITE
FREKOTE700-NC
releasesepoxies,polyesterresins,thermoplastics,rubber
comp ndsandmostothermoldedpolymers.
TYPICALPROPERTIESOFUNCUREDMATERIAL
SpecificGravity@ 25 C 0.755 to0.764
LMS
FlashPoint-SeeSDS
GENERALINFORMATION
Thisproductisnotrecommendedforuseinpureoxygen
and/oroxygenrichsystemsandshouldnotbeselectedas
asealantforchlorineorotherstrongoxidizing materials.
Forsafehandlinginformationonthisproduct,consultthe
SafetyDataSheet(SDS).
MoldPreparation
Cleaning:
Moldsurfacesmustbethor ghlycleanedanddried.Alltraces
ofpriorreleasemustberemoved.Thismaybeaccomplished
byusing Frekote
PMCorothersuitablecleaner. Frekote
915WB orlightabrasivescanbeusedforheavybuild-up.
SealingNew/RepairedMolds:
Occasionally,greenorfreshlyrepairedmoldsarerushedinto
servicepriortocompletecurecausinganincreasedam ntof
freestyreneonthemoldsurface.Freshor”productionline”
repairs,newfiberglassandepoxymoldssh ldbecuredper
manufacturer’sinstructions,usuallyaminimumof2-3weeks
at22 Cbeforestartingfull-scaleproduction.Fullycured
previ slyunusedmoldssh ldbesealedbeforeuse.This
canbeaccomplishedbyapplyingonetotwocoatsof an
appropriate Frekote
moldsealer, followingthedirectionsfor
useinstructions. AllowfullcureoftheappropriateFrekote
moldsealerbeforey applythefirstcoatofLOCTITE
FREKOTE700-NC as tlinedinthedirectionsofuse.
Directionsforuse:
1.LOCTITE
FREKOTE700-NC canbeappliedtomold
surfacesatromtemperatureupto135 Cbyspraying,
brushingorwipingwithacleanlint-free,cloth.When
sprayingensureadryairs rceisusedoruseanairless
spraysystem.Alwaysuseinawellventilatedarea.
2.Wipeorsprayonasmoth,thin,continu s,wet
film. Avoidwipingorsprayingoverthesameareathat
wasjustcoateduntilthesolventhasevaporated.If
spraying,holdnozzle20 to30cmfrommoldsurface.Itis
suggestedthatsmallareasbecoated,working
progressivelyfromonesideofthemoldtotheother.
3.Initially,apply2 to3basecoatsallowing5 to10 minutes
betweencoatsforsolventevaporation .
4.Allowthefinalcoattocurefor15 to20minutesat22 C.
5.Maximumreleaseswillbeobtainedasthemoldsurface
becomesconditionedtoLOCTITE
FREKOTE700-NC
. Performancecanbe enhancedbyre-coatingonce,after
thefirstfewinitialpulls.
6.Whenanyreleasedifficultyisexperienced,theareain
questioncanbe”t ched-up”byre-coatingtheentire
moldsurfaceorjustthoseareaswherereleasedifficultyis
occurring.
7.NOTE: LOCTITE
FREKOTE700-NC ismoisture
sensitive,keepcontainertightlyclosedwhennotinuse.
Theproductsh ldalwaysbeusedinawellventilated
area.
8.Precaution: Usersofclosedmoldsystems(rotomolding)
mustbecertainthatsolventevaporationiscompleteand
thatallsolventvaporshavebeenventilatedfromthemold
cavitypriortoclosingthemold.Anoil-freecompressedair
s rcecanbeusedtoassistinevaporationofsolvents
andventilationofthemoldcavity.
TDSLOCTITE
FREKOTE700-NC , January-2015
MoldTouchup
T chupcoatssh ldonlybeappliedtoareaswherepor
releaseisnoticedandsh ldbeappliedusingthesame
methodasbasecoats.Thiswillreducethepossibilityof
releaseagentorpolymerbuild-up.Thefrequencyoft chups
willdependonthepolymertype,moldconfiguration,and
abrasionparameters.
LoctiteMaterialSpecification
LMS
LMSdated May-10,2006. Testreportsforeachbatchare
availablefortheindicatedproperties. LMStestreportsinclude
selectedQCtestparametersconsideredappropriateto
specificationsforcustomeruse. Additionally,comprehensive
controlsareinplacetoassureproductqualityand
consistency. Specialcustomerspecificationrequirementsmay
becordinatedthr ghHenkel Quality.
Storage
Theproductisclassifiedasflammableandmustbestoredin
anappropriatemannerincompliancewithrelevant
regulations. Donotstorenearoxidizingagentsorcombustible
materials. Storeproductintheunopenedcontainerinadry
location. Storageinformationmayalsobeindicatedonthe
productcontainerlabelling.
OptimalStorage: 8 Cto21 C. Storagebelow8 Cor
greaterthan28 Ccanadverselyaffectproductproperties.
Materialremovedfromcontainersmaybecontaminatedduring
use. Donotreturnproducttotheoriginalcontainer. Henkel
cannotassumeresponsibilityforproductwhichhasbeen
contaminatedorstoredunderconditionsotherthanthose
previ slyindicated. Ifadditionalinformationisrequired,
pleasecontacty rlocalTechnicalServiceCenteror
CustomerServiceRepresentive.
Conversions
( Cx1.8)+32= F
kV/mmx25.4=V/mil
mm/25.4=inches
m/25.4=mil
Nx0.225=lb
N/mmx5.71=lb/in
N/mm x145=psi
MPax145=psi
N m x 8.851= lb in
N mx0.738=lb ft
N mm x0.142=oz in
mPa s=cP
Note:
TheinformationprovidedinthisTechnicalDataSheet(TDS)includingthe
recommendationsforuseandapplicationoftheproductarebasedon r
knowledgeandexperienceoftheproductasatthedateofthisTDS.Theproduct
canhaveavarietyofdifferentapplicationsaswellasdifferingapplicationand
workingconditionsiny renvironmentthatarebeyond rcontrol.Henkelis,
therefore,notliableforthesuitabilityof rproductfortheproductionprocesses
andconditionsinrespectofwhichy usethem,aswellastheintended
applicationsandresults.Westronglyrecommendthaty carry ty rown
priortrialstoconfirmsuchsuitabilityof rproduct.
AnyliabilityinrespectoftheinformationintheTechnicalDataSheetoranyother
writtenororalrecommendation(s)regardingtheconcernedproductisexcluded,
exceptifotherwiseexplicitlyagreedandexceptinrelationtodeathorpersonal
injurycausedby rnegligenceandanyliabilityunderanyapplicablemandatory
productliabilitylaw.
IncaseproductsaredeliveredbyHenkelBelgiumNV,HenkelElectronic
MaterialsNV,HenkelNederlandBV,HenkelTechnologiesFranceSASand
HenkelFranceSApleaseadditionallynotethefollowing:
IncaseHenkelw ldbeneverthelessheldliable,onwhateverlegalgr nd,
Henkel sliabilitywillinnoeventexceedtheam ntoftheconcerneddelivery.
IncaseproductsaredeliveredbyHenkelColombiana,S.A.S.thefollowing
disclaimerisapplicable:
TheinformationprovidedinthisTechnicalDataSheet(TDS)includingthe
recommendationsforuseandapplicationoftheproductarebasedon r
knowledgeandexperienceoftheproductasatthedateofthisTDS.Henkelis,
therefore,notliableforthesuitabilityof rproductfortheproductionprocesses
andconditionsinrespectofwhichy usethem,aswellastheintended
applicationsandresults.Westronglyrecommendthaty carry ty rown
priortrialstoconfirmsuchsuitabilityof rproduct.
AnyliabilityinrespectoftheinformationintheTechnicalDataSheetoranyother
writtenororalrecommendation(s)regardingtheconcernedproductisexcluded,
exceptifotherwiseexplicitlyagreedandexceptinrelationtodeathorpersonal
injurycausedby rnegligenceandanyliabilityunderanyapplicablemandatory
productliabilitylaw.
IncaseproductsaredeliveredbyHenkelCorporation,ResinTechnology
Group,Inc.,orHenkelCanadaCorporation,thefollowingdisclaimeris
applicable:
Thedatacontainedhereinarefurnishedforinformationonlyandarebelievedto
bereliable.Wecannotassumeresponsibilityfortheresultsobtainedbyothers
overwhosemethodswehavenocontrol.Itistheuser’sresponsibilityto
determinesuitabilityfortheuser’spurposeofanyproductionmethodsmentioned
hereinandtoadoptsuchprecautionsasmaybeadvisablefortheprotectionof
propertyandofpersonsagainstanyhazardsthatmaybeinvolvedinthehandling
andusethereof.Inlightoftheforegoing,HenkelCorporationspecifically
disclaimsallwarrantiesexpressedorimplied,includingwarrantiesof
merchantabilityorfitnessforaparticularpurpose,arisingfromsaleoruse
ofHenkelCorporation sproducts.HenkelCorporationspecifically
disclaimsanyliabilityforconsequentialorincidentaldamagesofanykind,
includinglostprofits.Thediscussionhereinofvari sprocessesor
compositionsisnottobeinterpretedasrepresentationthattheyarefreefrom
dominationofpatentsownedbyothersorasalicenseunderanyHenkel
Corporationpatentsthatmaycoversuchprocessesorcompositions.We
recommendthateachprospectiveusertesthisproposedapplicationbefore
repetitiveuse,usingthisdataasaguide.Thisproductmaybecoveredbyoneor
moreUnitedStatesorforeignpatentsorpatentapplications.
Trademarkusage
Exceptasotherwisenoted,alltrademarksinthisdocumentare trademarksof
HenkelCorporationintheU.S.andelsewhere.
denotesatrademark
registeredintheU.S.PatentandTrademarkOffice.
Reference0.1
Americas
+860.571.5100
Europe
+49.89.320800.1800
Asia
+86.21.2891.8863
Forthemostdirectaccesstolocalsalesandtechnicalsupportvisitwww.henkel.com/industrial
by | Sep 27, 2025
TechnicalDataSheet
LOCTITE
FREKOTE700-NC
Knownas700-NC
January-2015
PRODUCTDESCRIPTION
LOCTITE
FREKOTE 700-NC providesthefollowing
productcharacteristics:
Technology MoldRelease
Appearance Clear,colorless
LMS
ChemicalType SolventBasedPolymer
Odor Solvent
Cure Romtemperaturecure
CuredThermalStability 400 C
Application ReleaseCoatings
ApplicationTemperature13 to135 C
SpecificBenefit Nochlorinatedsolvents
Highglossfinish
Highslip
Nocontaminatingtransfer
Nomoldbuild-up
LOCTITE
FREKOTE 700-NC offersexcellentrelease
propertiesforthemostdemandingapplicationsandisagreat
all-purposereleaseagent.LOCTITE
FREKOTE700-NC
releasesepoxies,polyesterresins,thermoplastics,rubber
comp ndsandmostothermoldedpolymers.
TYPICALPROPERTIESOFUNCUREDMATERIAL
SpecificGravity@ 25 C 0.755 to0.764
LMS
FlashPoint-SeeSDS
GENERALINFORMATION
Thisproductisnotrecommendedforuseinpureoxygen
and/oroxygenrichsystemsandshouldnotbeselectedas
asealantforchlorineorotherstrongoxidizing materials.
Forsafehandlinginformationonthisproduct,consultthe
SafetyDataSheet(SDS).
MoldPreparation
Cleaning:
Moldsurfacesmustbethor ghlycleanedanddried.Alltraces
ofpriorreleasemustberemoved.Thismaybeaccomplished
byusing Frekote
PMCorothersuitablecleaner. Frekote
915WB orlightabrasivescanbeusedforheavybuild-up.
SealingNew/RepairedMolds:
Occasionally,greenorfreshlyrepairedmoldsarerushedinto
servicepriortocompletecurecausinganincreasedam ntof
freestyreneonthemoldsurface.Freshor”productionline”
repairs,newfiberglassandepoxymoldssh ldbecuredper
manufacturer’sinstructions,usuallyaminimumof2-3weeks
at22 Cbeforestartingfull-scaleproduction.Fullycured
previ slyunusedmoldssh ldbesealedbeforeuse.This
canbeaccomplishedbyapplyingonetotwocoatsof an
appropriate Frekote
moldsealer, followingthedirectionsfor
useinstructions. AllowfullcureoftheappropriateFrekote
moldsealerbeforey applythefirstcoatofLOCTITE
FREKOTE700-NC as tlinedinthedirectionsofuse.
Directionsforuse:
1.LOCTITE
FREKOTE700-NC canbeappliedtomold
surfacesatromtemperatureupto135 Cbyspraying,
brushingorwipingwithacleanlint-free,cloth.When
sprayingensureadryairs rceisusedoruseanairless
spraysystem.Alwaysuseinawellventilatedarea.
2.Wipeorsprayonasmoth,thin,continu s,wet
film. Avoidwipingorsprayingoverthesameareathat
wasjustcoateduntilthesolventhasevaporated.If
spraying,holdnozzle20 to30cmfrommoldsurface.Itis
suggestedthatsmallareasbecoated,working
progressivelyfromonesideofthemoldtotheother.
3.Initially,apply2 to3basecoatsallowing5 to10 minutes
betweencoatsforsolventevaporation .
4.Allowthefinalcoattocurefor15 to20minutesat22 C.
5.Maximumreleaseswillbeobtainedasthemoldsurface
becomesconditionedtoLOCTITE
FREKOTE700-NC
. Performancecanbe enhancedbyre-coatingonce,after
thefirstfewinitialpulls.
6.Whenanyreleasedifficultyisexperienced,theareain
questioncanbe”t ched-up”byre-coatingtheentire
moldsurfaceorjustthoseareaswherereleasedifficultyis
occurring.
7.NOTE: LOCTITE
FREKOTE700-NC ismoisture
sensitive,keepcontainertightlyclosedwhennotinuse.
Theproductsh ldalwaysbeusedinawellventilated
area.
8.Precaution: Usersofclosedmoldsystems(rotomolding)
mustbecertainthatsolventevaporationiscompleteand
thatallsolventvaporshavebeenventilatedfromthemold
cavitypriortoclosingthemold.Anoil-freecompressedair
s rcecanbeusedtoassistinevaporationofsolvents
andventilationofthemoldcavity.
TDSLOCTITE
FREKOTE700-NC , January-2015
MoldTouchup
T chupcoatssh ldonlybeappliedtoareaswherepor
releaseisnoticedandsh ldbeappliedusingthesame
methodasbasecoats.Thiswillreducethepossibilityof
releaseagentorpolymerbuild-up.Thefrequencyoft chups
willdependonthepolymertype,moldconfiguration,and
abrasionparameters.
LoctiteMaterialSpecification
LMS
LMSdated May-10,2006. Testreportsforeachbatchare
availablefortheindicatedproperties. LMStestreportsinclude
selectedQCtestparametersconsideredappropriateto
specificationsforcustomeruse. Additionally,comprehensive
controlsareinplacetoassureproductqualityand
consistency. Specialcustomerspecificationrequirementsmay
becordinatedthr ghHenkel Quality.
Storage
Theproductisclassifiedasflammableandmustbestoredin
anappropriatemannerincompliancewithrelevant
regulations. Donotstorenearoxidizingagentsorcombustible
materials. Storeproductintheunopenedcontainerinadry
location. Storageinformationmayalsobeindicatedonthe
productcontainerlabelling.
OptimalStorage: 8 Cto21 C. Storagebelow8 Cor
greaterthan28 Ccanadverselyaffectproductproperties.
Materialremovedfromcontainersmaybecontaminatedduring
use. Donotreturnproducttotheoriginalcontainer. Henkel
cannotassumeresponsibilityforproductwhichhasbeen
contaminatedorstoredunderconditionsotherthanthose
previ slyindicated. Ifadditionalinformationisrequired,
pleasecontacty rlocalTechnicalServiceCenteror
CustomerServiceRepresentive.
Conversions
( Cx1.8)+32= F
kV/mmx25.4=V/mil
mm/25.4=inches
m/25.4=mil
Nx0.225=lb
N/mmx5.71=lb/in
N/mm x145=psi
MPax145=psi
N m x 8.851= lb in
N mx0.738=lb ft
N mm x0.142=oz in
mPa s=cP
Note:
TheinformationprovidedinthisTechnicalDataSheet(TDS)includingthe
recommendationsforuseandapplicationoftheproductarebasedon r
knowledgeandexperienceoftheproductasatthedateofthisTDS.Theproduct
canhaveavarietyofdifferentapplicationsaswellasdifferingapplicationand
workingconditionsiny renvironmentthatarebeyond rcontrol.Henkelis,
therefore,notliableforthesuitabilityof rproductfortheproductionprocesses
andconditionsinrespectofwhichy usethem,aswellastheintended
applicationsandresults.Westronglyrecommendthaty carry ty rown
priortrialstoconfirmsuchsuitabilityof rproduct.
AnyliabilityinrespectoftheinformationintheTechnicalDataSheetoranyother
writtenororalrecommendation(s)regardingtheconcernedproductisexcluded,
exceptifotherwiseexplicitlyagreedandexceptinrelationtodeathorpersonal
injurycausedby rnegligenceandanyliabilityunderanyapplicablemandatory
productliabilitylaw.
IncaseproductsaredeliveredbyHenkelBelgiumNV,HenkelElectronic
MaterialsNV,HenkelNederlandBV,HenkelTechnologiesFranceSASand
HenkelFranceSApleaseadditionallynotethefollowing:
IncaseHenkelw ldbeneverthelessheldliable,onwhateverlegalgr nd,
Henkel sliabilitywillinnoeventexceedtheam ntoftheconcerneddelivery.
IncaseproductsaredeliveredbyHenkelColombiana,S.A.S.thefollowing
disclaimerisapplicable:
TheinformationprovidedinthisTechnicalDataSheet(TDS)includingthe
recommendationsforuseandapplicationoftheproductarebasedon r
knowledgeandexperienceoftheproductasatthedateofthisTDS.Henkelis,
therefore,notliableforthesuitabilityof rproductfortheproductionprocesses
andconditionsinrespectofwhichy usethem,aswellastheintended
applicationsandresults.Westronglyrecommendthaty carry ty rown
priortrialstoconfirmsuchsuitabilityof rproduct.
AnyliabilityinrespectoftheinformationintheTechnicalDataSheetoranyother
writtenororalrecommendation(s)regardingtheconcernedproductisexcluded,
exceptifotherwiseexplicitlyagreedandexceptinrelationtodeathorpersonal
injurycausedby rnegligenceandanyliabilityunderanyapplicablemandatory
productliabilitylaw.
IncaseproductsaredeliveredbyHenkelCorporation,ResinTechnology
Group,Inc.,orHenkelCanadaCorporation,thefollowingdisclaimeris
applicable:
Thedatacontainedhereinarefurnishedforinformationonlyandarebelievedto
bereliable.Wecannotassumeresponsibilityfortheresultsobtainedbyothers
overwhosemethodswehavenocontrol.Itistheuser’sresponsibilityto
determinesuitabilityfortheuser’spurposeofanyproductionmethodsmentioned
hereinandtoadoptsuchprecautionsasmaybeadvisablefortheprotectionof
propertyandofpersonsagainstanyhazardsthatmaybeinvolvedinthehandling
andusethereof.Inlightoftheforegoing,HenkelCorporationspecifically
disclaimsallwarrantiesexpressedorimplied,includingwarrantiesof
merchantabilityorfitnessforaparticularpurpose,arisingfromsaleoruse
ofHenkelCorporation sproducts.HenkelCorporationspecifically
disclaimsanyliabilityforconsequentialorincidentaldamagesofanykind,
includinglostprofits.Thediscussionhereinofvari sprocessesor
compositionsisnottobeinterpretedasrepresentationthattheyarefreefrom
dominationofpatentsownedbyothersorasalicenseunderanyHenkel
Corporationpatentsthatmaycoversuchprocessesorcompositions.We
recommendthateachprospectiveusertesthisproposedapplicationbefore
repetitiveuse,usingthisdataasaguide.Thisproductmaybecoveredbyoneor
moreUnitedStatesorforeignpatentsorpatentapplications.
Trademarkusage
Exceptasotherwisenoted,alltrademarksinthisdocumentare trademarksof
HenkelCorporationintheU.S.andelsewhere.
denotesatrademark
registeredintheU.S.PatentandTrademarkOffice.
Reference0.1
Americas
+860.571.5100
Europe
+49.89.320800.1800
Asia
+86.21.2891.8863
Forthemostdirectaccesstolocalsalesandtechnicalsupportvisitwww.henkel.com/industrial
by | Sep 27, 2025
1726 Floradale Ave., So. El Monte, CA 91733 | 626.443.8983 | sales@FinishKare.com | FinishKare.com
Product Data Sheet
1000P
Hi Low Paste Wax
Premium Mold Release Wax
Description
Finish Kare’s 1000P Hi Low Paste Wax is one of
our very popular product . It is part of the 1000 Mold Release
Wax Series, each formulated with a unique blend of synthetic
waxes and solvents to get specifically desired results.
1000P does exceptionally well in high exothermic conditions
and provides easy multiple releases.
Features & Benefits
High Temp Tolerance
Withstands high temperature exothermic reactions
of resins and does multiple releases easily.
Good for up to 275 F or 135 C.
Unique Wax Makeup
Contains carnauba wax, synthetic waxes and high
temperature resistant resins for effective multiple
releases of composite parts.
High Gloss Finish
Buffing out the final coat will result in a high gloss
finish
The hard, shiny film protects the molds from
intensive wear and heat and creates smoother,
shinier parts
Clean & Seal
Prior to any mold release wax application, we highly
recommend all molds be cleaned and sealed using our #69
Mold Cleaner and Stripper or #135 80 for a deeper clean and
our #86 Seal Kote to seal up any porosity.
Application Process
Step 1: Apply # 1000P, Hi Low Mold Release Wax in Five (5)
separate applications. Make sure that each coat is dry prior to
wiping. Please criss cross each application for assuring the
complete coverage. Apply wax in a circular motion to work the
wax in.
Step 2: Allow 30 minutes to set after the final wipe. Then re
wipe, pour the first part and release it.
Step 3: After releasing the part gently wipe the mold, then
apply one more coat of wax and release one more part.
AT THIS POINT, MOLD IS CURED TO THE POINT THAT
MULTIPLE RELEASES ARE POSSIBLE.
***Additional Release Tricks***
When a part gets a little hard to pull, apply one coat of
#1000L, Hi Low Liquid Wax, let it dry and wipe lightly. Run
more parts and apply # 1000L as needed. Use of # 1000L helps
in preventing wax buildup and thus helps in multiple releases.
Safety Data Sheet
Safety Date Sheets are available for all Finish Kare products
and should be consulted prior to use
Storage and Shelf Life
Store tightly closed container in a dry, cool place that is well
ventilated and below 46 C /104 F. Do not handle or store
near open flame, heat or other sources of ignition. Shelf life is
1 years from date of shipment.
IMITATIONS OF LIABILITY
To the best of our knowledge, the data presented here is true and accurate, but is
subject to change without prior notice. User is kindly requested to contact Finish Kare
Products to verify the correctness before specifying or ordering. Since we don t know
how the product will be used we cannot assume any responsibility for its use,
performance, or any injuries resulting from its use. Liability, if any, is limited to